Trunk Group Field Over 20 Characters Causes Server to Terminate

Article #ETM245B

Synopsis

The Trunk Group field on the Channel Map tab of the Span Configuration dialog box can only accept entries of 20 characters or less. Longer entries cause the ETM® Server to terminate unexpectedly.

Versions Affected

ETM® System v3.0xIn v4.0 of the ETM System, the Trunk Group field will prevent entry of more than 20 characters.

Known Workarounds

The database rejects the offending entry, so the value is unchanged when the ETM Server restarts. Type an entry of 20 or fewer characters in the Trunk Group field.

Last Update: 09/08/02

SecureLogix Corporation

13750 San Pedro, Suite 230 • San Antonio, Texas 78232 • (210) 402-9669 • www.securelogix.com

Support (877) SLC-4HELP • EMAIL support@securelogix.com • http://support.securelogix.com

ETM, SecureLogix, SecureLogix Corporation, TeleWatch Secure, TWSA, the ETM Emblem, the SecureLogix Diamond Emblem, and the ETM Application Suite Emblems are trademarks or registered trademarks of SecureLogix Corporation in the U.S.A. and other countries. All other trademarks mentioned herein are believed to be trademarks of their respective owners.

© Copyright 2002 SecureLogix Corporation. All Rights Reserved.
U.S. Patents No. US 6,249,575 B1 and US 6,320,948 B1.
U.S. and Foreign Patents Pending.

This product includes:
Data Encryption Standard Software developed by Eric Young (eay@mincom.oz.au)
© Copyright 1995 Eric Young. All Rights Reserved.
Style Report software owned and licensed exclusively by InetSoft Technology Corp.
© Copyright 1996-2000 InetSoft Technology Corp. All Rights Reserved.

Published on December 3, 2002  |  Updated on August 9, 2021

Related Articles

Need Support?
Can't find the answer you're looking for? Don't worry we're here to help!