ORA-01466 error when opening the TeleAudit® Usage Manager

Article #ETMD673

Versions Affected

ETM® System v3.0 and later

Symptom

When trying to open the TeleAudit Usage Manager, the following error occurred:

ORA-01466: unable to read data – table definition has changedDescription

This error occurs when the system time of the computer on which the database is installed is older than the creation date of the database, most likely caused by manually changing the system clock.

Solution

Reset the system clock to the current date and time.

Last Updated

5/5/2004

SecureLogix Corporation • 13750 San Pedro, Suite 230 • San Antonio, Texas 78232 • (210) 402-9669 • www.securelogix.com

Support (877) SLC-4HELP • EMAIL support@securelogix.com • http://support.securelogix.com

ETM, SecureLogix, SecureLogix Corporation, TeleWatch Secure, TWSA, the ETM Emblem, the SecureLogix Diamond Emblem, and the ETM Application Suite Emblems are trademarks or registered trademarks of SecureLogix Corporation in the U.S.A. and other countries. All other trademarks mentioned herein are believed to be trademarks of their respective owners.

© Copyright 2004 SecureLogix Corporation. All Rights Reserved.

U.S. Patents No. US 6,249,575 B1, US 6,320,948 B1, US 6,542,592 B1, US 6,687,353 B1,
US 6,700,964 B1, US 6,718,024 B1, and US 6,735,291 B1. U.S. and Foreign Patents Pending.

Published on June 7, 2004  |  Updated on July 26, 2021